当前位置: 首页 > 详情页

Blood flow reduction of covered small side branches after flow diverter treatment: A computational fluid hemodynamic quantitative analysis

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE ◇ EI

机构: [a]Australia School of Advanced Medicine, Macquarie University, 2 Technology Place, 2109 Sydney, Australia [b]Neurosurgery Department of Xuanwu Hospital, Capital Medical University, 45 Changchun Street, 100054 Beijing, PR China [c]Neurosurgery Department of Second Hospital of Beijing Armed Police Corps, Yuetan North Avenue, 100037 Beijing, PR China [d]Monash Medical Centre, Monash University, 3800 Victoria, Australia
出处:
ISSN:

关键词: Blood flow Computational fluid dynamics Flow diverter device Intracranial aneurysms

摘要:
Small side branches related brain infarction remains one of the major concerns for flow-diverter devices. However, among several factors, whether this high-profile stent would significantly block blood flow into small side branches remains unclear. The authors quantitatively evaluate blood flow reduction due to the deployment of flow-diverter devices using computational fluid dynamics approach. Thirty one patient-specific anterior inferior cerebellar artery geometries were employed. The flow-diverter device was hypothetically embedded into the basilar trunk, and to cover the anterior inferior cerebellar arteries. The blood flow reduction of each anterior inferior cerebellar artery following flow-diverter device deployment was calculated, with independent validations for both inflow and outflow conditions. Efficient diameters of the anterior inferior cerebellar arteries were calculated to evaluate any correlation with blood flow reduction after flow-diverter devices. The blood flow reduction ratio was shown to be 3.61 +/- 1.94%. There was moreover no significant difference of either inflow or outflow boundary conditions during the simulation. The results were calculated approximately as a modest linear correlation between the blood flow reduction ratio and the size of anterior anterior inferior cerebellar arteries which had a mean efficient diameter of 1.12 +/- 0.36 mm (range from 0.31 mm to 1.91 mm), and the R-2 was 0.361. When covered by flowdiverter devices, the mechanical blood flow reduction in anterior inferior cerebellar arteries was found to be low with a maximum value estimated to be less than 8%. Therefore, mechanical blood flow reduction is probably not the leading factor contributing to small side branches related brain infarction. (C) 2015 Elsevier Ltd. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 3 区 生物
小类 | 3 区 工程:生物医学 4 区 生物物理
最新[2023]版:
大类 | 3 区 医学
小类 | 2 区 生物物理 3 区 工程:生物医学
JCR分区:
出版当年[2013]版:
Q2 ENGINEERING, BIOMEDICAL Q3 BIOPHYSICS
最新[2023]版:
Q3 ENGINEERING, BIOMEDICAL Q3 BIOPHYSICS

影响因子: 最新[2023版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者机构: [a]Australia School of Advanced Medicine, Macquarie University, 2 Technology Place, 2109 Sydney, Australia [b]Neurosurgery Department of Xuanwu Hospital, Capital Medical University, 45 Changchun Street, 100054 Beijing, PR China [*1]Neurosurgery Department of Xuanwu Hospital,Changchun Street,100054 Beijing,PR China.
通讯作者:
通讯机构: [*1]Neurosurgery Department of Xuanwu Hospital,Changchun Street,100054 Beijing,PR China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院