当前位置: 首页 > 详情页

Contrast-Enhanced Whole-Heart Coronary Magnetic Resonance Angiography at 3 T With Radial EPI

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Departments of Radiology and Biomedical Engineering, Northwestern University, Chicago, Illinois, USA. [2]Department of Radiology, Capital Medical University, Xuanwu Hospital, Beijing, China. [3]Siemens Medical Solutions USA, Inc., Chicago, Illinois, USA. [4]Biomedical Imaging Research Institute and Department of Biomedical Sciences, Cedars-Sinai Medical Center and University of California, Los Angeles, California, USA.
出处:
ISSN:

关键词: magnetic resonance angiography coronary arteries radial sampling EPI contrast agents

摘要:
Whole-heart coronary magnetic resonance angiography is a promising method for detecting coronary artery disease. However, the imaging time is relatively long (typically 10-15 min). The goal of this study was to implement a radial echo planar imaging sequence for contrast-enhanced whole-heart coronary magnetic resonance angiography, with the aim of combining the scan efficiency of echo planar imaging with the motion insensitivity of radial k-space sampling. A self-calibrating phase correction technique was used to correct for off-resonance effects, trajectory measurement was used to correct for k-space trajectory errors, and variable density sampling was used in the partition direction to reduce streaking artifacts. Seven healthy volunteers and two patients were scanned with the proposed radial echo planar imaging sequence, and the images were compared with a traditional gradient echo and Xray angiography techniques, respectively. Whole-heart images with the radial EPI technique were acquired with a resolution of 1.0 x 1.0 x 2.0 mm(3) in a scan time of 5 min. In healthy volunteers, the average image quality scores and visualized vessel lengths of the RCA and LAD were similar for the radial EPI and gradient echo techniques (P value > 0.05 for all). Anecdotal patient studies showed excellent agreement of the radial EPI technique with X-ray angiography. Magn Reson Med 66:82-91, 2011. (C) 2011 Wiley-Liss, Inc.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2010]版:
大类 | 3 区 医学
小类 | 2 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2009]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2009版] 出版当年五年平均 出版前一年[2008版] 出版后一年[2010版]

第一作者:
第一作者机构: [1]Departments of Radiology and Biomedical Engineering, Northwestern University, Chicago, Illinois, USA.
通讯作者:
通讯机构: [*1]Davis Building, Suite G-140, 8700 Beverly Blvd., Los Angeles, CA 90048.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:17009 今日访问量:0 总访问量:906 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院