Clinical application of proportional assist ventilation in very low birth weight infants with ventilator dependence

| 认领 | 导出 |

文献详情

资源类型:

收录情况: ◇ 统计源期刊 ◇ 北大核心 ◇ CSCD-E

机构: [1]Bayi Children's Hospital, Military General Hospital of Beijing People's Liberation Army, Beijing 100700, China
出处:
ISSN:

关键词: Conventional assist/control ventilation Proportional assist ventilation Very low birth weight infant

摘要:
Objective: To study the effect of proportional assist ventilation (PAV) on physiology and respiratory mechanics in very low birth weight (VLBW) infants with ventilator dependence by comparison with conventional assist/control (A/C) ventilation. Methods: Forty-six infants with ventilator dependence were randomly divided into two groups according to the ventilation model: PAV (n = 23) and A/C (n = 23). The gain of resistive and elastic unloading was set based on the runway method in the PAV group. Ventilation parameters were set based on the conventional method in the A/C group. Infants were observed for 30 minutes three times per day for three consecutive days. Arterial gas analysis results, transcutaneous saturation of oxygen (SPO 2), heart rate, blood pressure (BP), respiratory rate (RR), mean airway pressure (MAP), peak inspiratory pressure (PIP), tide volume (VT), minute volume (MV) and oxygenation index(OI), were compared between the two groups. Results: Compared with the A/C group, PaO 2 and OI in the PAV group were significantly higher while PIP and MAP were significantly lower. There were no significant differences in FiO 2, SPO 2, pH, PaCO 2, PEEP, VT, MV and RR between the two groups. Although mean arterial blood pressure and heart rate in the PAV group were not different from the A/C group, beat-to-beat variabilities in systolic and diastolic arterial blood pressure were significantly lower in the PAV group than in the A/C group. Conclusions: PAV may safely maintain gas exchange at lower airway pressures compared with A/C ventilation in VLBW infants. It can also improve oxygenation and infant-ventilator synchronization.

语种:
第一作者:
第一作者机构: [1]Bayi Children's Hospital, Military General Hospital of Beijing People's Liberation Army, Beijing 100700, China
推荐引用方式(GB/T 7714):

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院