Imaging collector channel entrance with a new intraocular micro-probe swept-source optical coherence tomography

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Ophthalmol, Beijing, Peoples R China; [2]Xuzhou 1st Hosp, Dept Ophthalmol, Xuzhou, Jiangsu, Peoples R China; [3]Capital Med Univ, Beijing Tongren Hosp, Dept Ophthalmol, 1 Dongjiaominxiang, Beijing 100730, Peoples R China; [4]Univ Washington, Dept Bioengn, Seattle, WA 98195 USA; [5]Univ Washington, Dept Ophthalmol, Seattle, WA 98195 USA
出处:
ISSN:

关键词: catheter probe collector channel entrance Schlemm's canal SS-OCT trabecular meshwork

摘要:
PurposeTo describe the use of a newly developed side-viewing catheter probe to provide the cross-sectional images of collector channel entrance (CCE), achieved by swept-source optical coherence tomography (SS-OCT). MethodsA side-viewing SS-OCT catheter probe was developed that has a core probe diameter of 0.15mm and an outer diameter of 0.25mm, for the purpose of imaging CCEs within eye globe. Cadaver eyes harvested from swine and human were used to demonstrate its feasibility. For porcine eyes, the probe imaged the CCE by accessing the region of the aqueous plexus (AP) as well as along the inner wall (IW) of the trabecular meshwork (TM). For human eyes, the CCE images were captured by placing the probe within the lumen of the Schlemm's canal (SC) and along its IW. ResultsWith the optical coherence tomography (OCT) catheter probe, the CCE is well delineated as optically empty areas within the highly scattering sclera. In porcine eyes, images captured in the region of the AP demonstrate a large cavity with delicate tissue strands around the probe. The CCE can be identified at the outer margin of the AP. When imaged along the IW, the TM is discernable but difficult to be distinguished from the AP. In the human limbal regions, when placed within the lumen of the SC, the catheter probe fully occupies the potential space. TM is highly compact. The CCE can be identified at the outer wall of the SC. When imaged along the IW of TM, the SC and CCE can be identified. ConclusionThe intraocular SS-OCT catheter probe is feasible to provide the CCE images, indicating useful clinical applications to assist glaucoma surgery.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 3 区 医学
小类 | 2 区 眼科学
最新[2023]版:
大类 | 3 区 医学
小类 | 2 区 眼科学
JCR分区:
出版当年[2015]版:
Q1 OPHTHALMOLOGY
最新[2023]版:
Q1 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Ophthalmol, Beijing, Peoples R China;
通讯作者:
通讯机构: [3]Capital Med Univ, Beijing Tongren Hosp, Dept Ophthalmol, 1 Dongjiaominxiang, Beijing 100730, Peoples R China;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院