In vivo evaluation of an implantable magnetic suspending left ventricular assist device

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Beijing 100029, Peoples R China; [2]Beijing Inst Heart Lung & Blood Vessel Dis, Beijing, Peoples R China; [3]China Heart Biomed Inc, Suzhou, Jiangsu, Peoples R China; [4]Capital Med Univ, Beijing Anzhen Hosp, 2 Anzhen Rd, Beijing 100029, Peoples R China
出处:
ISSN:

关键词: Magnetically suspended blood pump CH-VAD Reliability Hemocompatibility In vivo evaluation

摘要:
Purpose: The CH-VAD is an implantable, fully magnetically suspended ventricular assist device developed by the China Heart Biomedical Corporation (Suzhou, China) for full cardiac support. This study was performed to evaluate the reliability, hemocompatibility and end-organ effects of CH-VAD in a 35-day animal model trial. Methods: The pump was implanted in 6 sheep. The pump inflow was inserted into the left ventricle and the outflow graft was anastomosed to the descending aorta. Data on pump function and the health condition of the animals, including hematologic and biochemical tests, were collected during the study period. When each study was determined to termination, the sheep were humanely euthanized and the end organs were examined macroscopically and histopathologically. Hemolysis was evaluated based on the amount of free hemoglobin in the plasma. Results: Except for one device that stopped operation on postoperative day 25 because of thrombus formation, the devices functioned normally until the scheduled termination. Gross examination of the pump interiors, inflow and outflow, and of the arterial anastomosis sites showed no significant abnormalities. Hematologic and biochemical test results were within normal limits during the study period. Macroscopic and histopathologic examinations of the explanted organs revealed no evidence of ischemia or infarction associated with the device implantation, except for small foci of infarction in the kidneys of two sheep. The free hemoglobin level in plasma peaked at 9.5 mg/dl on postoperative day 5. Conclusions: The CH-VAD system demonstrated promising reliability and blood-handling characteristics without obvious damage to end organs during a 35-day implantation in sheep.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 4 区 医学
小类 | 4 区 工程:生物医学 4 区 移植
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 工程:生物医学 4 区 移植
JCR分区:
出版当年[2013]版:
Q3 TRANSPLANTATION Q3 ENGINEERING, BIOMEDICAL
最新[2023]版:
Q3 TRANSPLANTATION Q4 ENGINEERING, BIOMEDICAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Beijing 100029, Peoples R China; [2]Beijing Inst Heart Lung & Blood Vessel Dis, Beijing, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Beijing 100029, Peoples R China; [4]Capital Med Univ, Beijing Anzhen Hosp, 2 Anzhen Rd, Beijing 100029, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院