Accuracy and reliability of computer-assisted semi-automated morphological analysis of intracranial aneurysms: an experimental study with digital phantoms and clinical aneurysm cases

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China [2]Department of Neurosurgery, The Hospital of Shunyi District Beijing, Beijing, China [3]Department of Neurosurgery, The Fourth Afliated Hospital of Harbin Medical University, Harbin, Hei Longjiang Province, China [4]Department of Neurosurgery, The Second Afliated Hospital of Anhui Medical University, He Fei, Anhui Province, China [5]Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, USA [6]Department of R&D, UnionStrong (Beijing) Technology Co. Ltd, Beijing, China
出处:
ISSN:

关键词: Intracranial aneurysm Rupture Angiography Digital subtraction Computer assisted

摘要:
Purpose Morphological parameters are very important for predicting aneurysm rupture. However, due to geometric radiographic distortion and plane/angle selection bias, the traditional manual measurements (MM) of aneurysm morphology are inaccurate and suffer from severe variability. Our study is to evaluate the accuracy and reliability of computer-assisted semi-automated measurement (CASAM) of intracranial aneurysms, which is a novel technique in aneurysm measurement. Methods An in-house software for CASAM was developed. Classical morphology indices including aneurysm diameter, neck size, height, width, volume, inflow angle, and aspect ratio were measured. To validate the accuracy and robustness of the semi-automated measurements, 20 digital intracranial aneurysm phantoms and 27 clinical aneurysms with different locations and sizes were measured using MM or CASAM. Results In the phantom study, although the inter-observer variability of both the MM and CASAM was very low, the manual measurements had higher errors (1.7-19.1%), while the CASAM yielded more accurate results (errors of 1.1-2.5%). The consistency test indicated that the CASAM results were highly consistent with the actual values (concordance correlation coefficient = 0.993). In the clinical study, CASAM showed better intraclass correlation coefficient values compared with MM. The inflow angle had low consistency in both groups. Conclusions We successfully developed a computer-assisted method to semi-automatically measure the morphological parameters of aneurysm. According to our study, CASAM of aneurysm morphological parameters is a more precise and reliable way than MM to obtain accurate aneurysm morphological parameters. This method is worthy of further studies to promote its clinical use.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 3 区 外科 4 区 工程:生物医学 4 区 核医学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 工程:生物医学 3 区 核医学 3 区 外科
JCR分区:
出版当年[2018]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q2 SURGERY Q3 ENGINEERING, BIOMEDICAL
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q2 SURGERY Q3 ENGINEERING, BIOMEDICAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者机构: [1]Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院