Holographic mixed-reality neuronavigation with a head-mounted device: technical feasibility and clinical application.

| 导出 | |

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Neurosurgery, Chinese PLA General Hospital [2]School of Medicine, Nankai University, Tianjin, China [3]Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing
出处:
ISSN:

关键词: mixed reality neuronavigation accuracy preoperative planning

摘要:
The authors aimed to evaluate the technical feasibility of a mixed-reality neuronavigation (MRN) system with a wearable head-mounted device (HMD) and to determine its clinical application and accuracy.A semiautomatic registration MRN system on HoloLens smart glasses was developed and tested for accuracy and feasibility. Thirty-seven patients with intracranial lesions were prospectively identified. For each patient, multimodal imaging-based holograms of lesions, markers, and surrounding eloquent structures were created and then imported to the MRN HMD. After a point-based registration, the holograms were projected onto the patient's head and observed through the HMD. The contour of the holograms was compared with standard neuronavigation (SN). The projection of the lesion boundaries perceived by the neurosurgeon on the patient's scalp was then marked with MRN and SN. The distance between the two contours generated by MRN and SN was measured so that the accuracy of MRN could be assessed.MRN localization was achieved in all patients. The mean additional time required for MRN was 36.3 ± 6.3 minutes, in which the mean registration time was 2.6 ± 0.9 minutes. A trend toward a shorter time required for preparation was observed with the increase of neurosurgeon experience with the MRN system. The overall median deviation was 4.1 mm (IQR 3.0 mm-4.7 mm), and 81.1% of the lesions localized by MRN were found to be highly consistent with SN (deviation < 5.0 mm). There was a significant difference between the supine position and the prone position (3.7 ± 1.1 mm vs 5.4 ± 0.9 mm, p = 0.001). The magnitudes of deviation vectors did not correlate with lesion volume (p = 0.126) or depth (p = 0.128). There was no significant difference in additional operating time between different operators (37.4 ± 4.8 minutes vs 34.6 ± 4.8 minutes, p = 0.237) or in localization deviation (3.7 ± 1.0 mm vs 4.6 ± 1.5 mm, p = 0.070).This study provided a complete set of a clinically applicable workflow on an easy-to-use MRN system using a wearable HMD, and has shown its technical feasibility and accuracy. Further development is required to improve the accuracy and clinical efficacy of this system.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 3 区 医学
小类 | 2 区 外科 3 区 临床神经病学
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 临床神经病学 2 区 外科
JCR分区:
出版当年[2019]版:
Q1 SURGERY Q2 CLINICAL NEUROLOGY
最新[2023]版:
Q1 SURGERY Q2 CLINICAL NEUROLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Department of Neurosurgery, Chinese PLA General Hospital [2]School of Medicine, Nankai University, Tianjin, China
共同第一作者:
通讯作者:
通讯机构: [1]Department of Neurosurgery, Chinese PLA General Hospital [*1]Chinese PLA General Hospital, Beijing, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16461 今日访问量:0 总访问量:871 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院