当前位置: 首页 > 详情页

Dynamical levels of plasma F1+2 and D-dimer in patients with acute cerebral infarction during intravenous urokinase thrombolysis

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Division of Neurology, Shijitan Hospital, Ninth Clinical Medical College of Beijing University, Beijing 100038, China [2]Xuanwu Hospital, Capital Medical University, Beijing 100053, China [3]First Hospital of Harbin Medical University, Harbin 150001, China
出处:
ISSN:

关键词: Urokinase thrombolysis fibrinolysis plasminogen

摘要:
Objective: To explore the value of dynamically monitored levels of plasma prothrombin fragment(1+2) (F1+2) and D-dimer in the process of thrombolysis with urokinase. Methods: Blood samples were collected at baseline and at hours 1, 2, 3, 6, 12, 24, 48, 72, and 96 after urokinase infusion finished. The levels of plasma F1+2 and D-dimer of 45 patients who received urokinase intravenous infusion were assayed by ELISA and fluorescent immunoassay, and analysed dynamically with their clinical outcomes. Results: The levels of plasma F1+2 and D-dimer in patients before urokinase thrombolysis were significantly higher than age- and gender-matched normal controls (all p < 0.05). After urokinase infusion was finished, three kinds of dynamic changes of plasma F1+2 and D-dimer with different clinical outcomes appeared. In effective subgroup (n = 30), the plasma D-dimer increased quickly and reached to the peak at the third hour, remained at the higher level for more than 24 hours, and then decreased gradually; while plasma F1+2 began to decrease at the second hour and promptly approached to its trough near the baseline, after 24 hours. In non-effective subgroup, the D-dimer was slightly higher than its baseline and much lower than that in the effective subgroup, and the most high level appeared at the sixth hour and decreased quickly; moreover, the peak of F1+2 appeared at the third hour and remained at high level for more than 40 hours, and then decreased to the trough which was near the baseline. In cerebral hemorrhage subgroup, the D-dimer peak (2551 +/- 68 mu g/l) appeared at the third hour, which was 1.5-fold higher than that in effective subgroup (1895 +/- 89 mu g/l), 5.0-fold higher than that in non-effective subgroup (531 +/- 46 mu g/l), and 6.0-fold higher than its baseline, and kept higher level for more than 72 hours; meanwhile, the F1+2 decreased remarkably and reached the trough which was far below its baseline. Conclusions: Plasma F1+2 and D-dimer levels are closely related to the different clinical outcomes after urokinase thrombolysis. Thrombotic-fibrinolytic imbalance might be one of the main reasons which affected the prognosis of ischemia stroke. Dynamic assay of the two biomarkers in plasma besides clinical observation might be helpful to predict the early prognosis of acute ischemia stroke during the process of urokinase thrombolysis. [Neurol Res 2009; 31: 367-370]

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2008]版:
大类 | 4 区 医学
小类 | 4 区 临床神经病学 4 区 神经科学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 临床神经病学 4 区 神经科学
JCR分区:
出版当年[2007]版:
Q3 CLINICAL NEUROLOGY Q3 NEUROSCIENCES
最新[2023]版:
Q3 CLINICAL NEUROLOGY Q4 NEUROSCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2007版] 出版当年五年平均 出版前一年[2006版] 出版后一年[2008版]

第一作者:
第一作者机构: [1]Division of Neurology, Shijitan Hospital, Ninth Clinical Medical College of Beijing University, Beijing 100038, China
通讯作者:
通讯机构: [2]Xuanwu Hospital, Capital Medical University, Beijing 100053, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:17095 今日访问量:1 总访问量:921 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院