Utilization of Pulsatile flow to Decellularize the Human Umbilical Arteries to Make Small-Caliber Blood Vessel Scaffolds

| 认领 | 导出 |

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Anzhen Hosp, Dept Cardiac Surg, Beijing 100029, Peoples R China; [2]Capital Med Univ, Anzhen Hosp, Dept Extracorporeal Circulat, Beijing 100029, Peoples R China; [3]Jiangsu Univ, Affiliated Hosp, Dept Cardiothorac Surg, Zhenjiang 212001, Peoples R China; [4]Capital Med Univ, Anzhen Hosp, Dept Extracorporeal Circulat, 2 Anzhen Rd, Beijing 100029, Peoples R China
出处:
ISSN:

关键词: Decellularization Human umbilical artery Scaffolds Small diameter blood vessel Vascular tissue engineering

摘要:
Purpose: To explore the effect of pulsatile flow in the decellularization process of small blood vessels. Methods: A total of 30 human umbilical cords were used in the current study. The umbilical cords were flushed with 0.25% trypsin/0.01% EDTA for 30 minutes, followed by treatment with 1% sodium dodecyl sulfate sodium dodecyl sulfate for 3 hours. The effectiveness of decellularization on the umbilical artery wall was analyzed by mechanical analysis. The scaffolds' biocompatibility was observed by co-culture with the human umbilical endothelial cells. Results: The maximum stress of the arteries before and after denuding was 3.55 +/- 0.42N and 3.50 +/- 0.43N, respectively. Under the pressure of 300 mmHg, 28 pieces of umbilical cords remained intact before and after the flushing, while 2 pieces ruptured under 300 mmHg. There was no significant difference in mechanical properties between flushed and control arteries. Isolated human umbilical endothelial cells grow and spread well on the decellularized umbilical artery scaffolds. Conclusions: Decellularization by pulsatile flow in human umbilical artery is a convenient, rapid and efficient approach to increase the availability of small caliber blood vessel scaffolds.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 4 区 医学
小类 | 4 区 心脏和心血管系统
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 心脏和心血管系统
JCR分区:
出版当年[2011]版:
Q4 CARDIAC & CARDIOVASCULAR SYSTEMS
最新[2023]版:
Q3 CARDIAC & CARDIOVASCULAR SYSTEMS

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者机构: [1]Capital Med Univ, Anzhen Hosp, Dept Cardiac Surg, Beijing 100029, Peoples R China; [3]Jiangsu Univ, Affiliated Hosp, Dept Cardiothorac Surg, Zhenjiang 212001, Peoples R China;
通讯作者:
通讯机构: [2]Capital Med Univ, Anzhen Hosp, Dept Extracorporeal Circulat, Beijing 100029, Peoples R China; [4]Capital Med Univ, Anzhen Hosp, Dept Extracorporeal Circulat, 2 Anzhen Rd, Beijing 100029, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16461 今日访问量:0 总访问量:871 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院