机构:[1]Department of Radiology, Beijing Chao‑Yang Hospital, Capital Medical University, 8 Gongren Tiyuchang Nanlu, Chaoyang District, Beijing 100020, China.[2]Department of Radiology, Xuanwu Hospital of Capital Medical University, No. 45, Chang‑Chun Street, Xicheng District, Beijing 100053, China.医技科室放射科首都医科大学宣武医院
Background Rest/stress myocardial CT perfusion (CTP) has high diagnostic value for coronary artery disease (CAD), but the additional value of resting CTP especially dual-energy CTP (DE-CTP) beyond coronary CT angiography (CCTA) in chest pain triage remains unclear. We aimed to evaluate the diagnostic accuracy of resting myocardial DE-CTP, and additional value in detecting CAD beyond CCTA (obstructive stenosis: >= 50%) in patients suspected of CAD. Methods In this prespecified subanalysis of 54 patients, we included patients suspected of CAD referred to invasive coronary angiography (ICA). Diagnostic accuracy of resting myocardial DE-CTP in detecting myocardial perfusion defects was assessed using resting N-13-ammonia positron emission tomography (PET) as the gold standard. Diagnostic accuracy of cardiac dual-energy CT in detecting flow-limiting stenoses (justifying revascularization) by CCTA combined with resting myocardial DE-CTP, using ICA plus resting N-13-ammonia PET as the gold standard. The CCTA and DE-CTP datasets derived from a single-phase scan performed with dual-energy mode. Results For detecting myocardial perfusion defects, DE-CTP demonstrated high diagnostic accuracy with a sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) of 95.52%, 85.93%, and 0.907 on a per-segment basis. For detecting flow-limiting stenoses by CCTA alone, sensitivity, specificity, and AUC were 100%, 56.47%, and 0.777 respectively on a per-vessel basis. For detecting flow-limiting stenoses by CCTA combined with resting myocardial DE-CTP, sensitivity, specificity, and AUC were 96.10%, 95.29% and 0.956 respectively on a per-vessel basis. Additionally, CCTA combined with resting myocardial DE-CTP detected five patients (9%) with no obstructive stenosis but with myocardial perfusion defects confirmed by ICA plus N-13-ammonia PET. Conclusions Resting cardiac DE-CTP demonstrates a high diagnostic accuracy in detecting myocardial perfusion defects and provides an additional clinical value by reducing rates of false-positive and false-negative patients beyond CCTA in patients suspected of CAD.
第一作者机构:[1]Department of Radiology, Beijing Chao‑Yang Hospital, Capital Medical University, 8 Gongren Tiyuchang Nanlu, Chaoyang District, Beijing 100020, China.
通讯作者:
推荐引用方式(GB/T 7714):
Li Wenhuan,Yu Fangfang,Liu Mingxi,et al.Clinical value of resting cardiac dual-energy CT in patients suspected of coronary artery disease[J].BMC MEDICAL IMAGING.2022,22(1):doi:10.1186/s12880-022-00761-1.
APA:
Li, Wenhuan,Yu, Fangfang,Liu, Mingxi&Yan, Chengxi.(2022).Clinical value of resting cardiac dual-energy CT in patients suspected of coronary artery disease.BMC MEDICAL IMAGING,22,(1)
MLA:
Li, Wenhuan,et al."Clinical value of resting cardiac dual-energy CT in patients suspected of coronary artery disease".BMC MEDICAL IMAGING 22..1(2022)