当前位置: 首页 > 详情页

Midterm Results of Intentional Celiac Artery Coverage During TEVAR for Type B Aortic Dissection

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Department of Vascular Surgery, Xiangya 2nd Hospital, and Hunan Provincial Great Vessel Medical Center, Central-South University, Chang Sha, Hunan, China. [2]Department of Vascular Surgery, XuanWu Hospital, Capital Medical University, Beijing, China
出处:
ISSN:

关键词: aortic dissection thoracic endovascular aortic repair celiac artery stent-graft aortic diameter endoleak intentional overstenting true lumen false lumen

摘要:
Purpose: To report the outcome of intended celiac artery coverage during thoracic endovascular aortic repair (TEVAR) for type B aortic dissection with an intinnal tear near the celiac artery (CA) orifice. Methods: Between 2007 and 2011, 13 patients (10 men; mean age 61.3 years, range 46-70) with type B aortic dissection underwent primary (n=9) or secondary (n=4) TEVAR with intentional CA coverage. Preoperative imaging was performed to confirm the existence of collateral circulation between the celiac artery and superior mesenteric artery. A short stent-graft was then deployed to cover both the entry tear and the CA. Follow-up was at 2 weeks; 1, 3, and 6 months; and every year thereafter. Preoperative diameters of the true and false lumens at the CA level, 8 cm above the CA, and at the aortic bifurcation, along with the maximum aortic diameter in the dissected segment, were compared to similar measurements at 6 months. Results: All stent-graft procedures were successful and without complication. No immediate or delayed endoleak was identified in 8 of 13 patients over a mean 25-month follow-up (range 3-38). The other 5 patients had type II endoleak on completion imaging; these all resolved within 3 months after operation. Postoperative blood liver function and amylase assays were normal in all patients. No abdominal symptoms or signs of spinal cord ischemia were discovered. Expansion of the true lumen after TEVAR was statistically significant vs. at baseline in both groups (primary p<0.001, secondary p=0.023). Both the false lumen and the entire aorta showed signs of shrinkage after TEVAR in the 2 groups as well, although only the secondary group showed significant change (p<0.005) vs. baseline. Conclusion: TEVAR with intentional CA coverage is effective in excluding an infradiaphragmatic entry tear near the CA level. The incidence of abdominal ischemia is low if collateral circulation has been confirmed preoperatively. Type II endoleak is a major complication, yet most cease under observation.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 3 区 医学
小类 | 2 区 外科 3 区 外周血管病
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 外科 3 区 外周血管病
JCR分区:
出版当年[2011]版:
Q1 SURGERY Q2 PERIPHERAL VASCULAR DISEASE
最新[2023]版:
Q2 SURGERY Q3 PERIPHERAL VASCULAR DISEASE

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者机构: [1]Department of Vascular Surgery, Xiangya 2nd Hospital, and Hunan Provincial Great Vessel Medical Center, Central-South University, Chang Sha, Hunan, China.
通讯作者:
通讯机构: [*1]Department of Vascular Surgery, Xiangya 2nd Hospital, Central-South University, 139 Renmin Middle Road, Chang Sha, Hunan 410011, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院